TMV2 and TMV3 are two approval schemes for thermostatic mixing valves, and they are aimed at different kinds of building. This guide sets out what each scheme covers, which settings usually call for which, what dual approval means, why supply pressure matters, and how to work out what is already fitted on your site.

A thermostatic mixing valve fitted on clean copper pipework against a painted wall

The short answer

TMV2 is the scheme for domestic-type use. Valves are tested to BS EN 1111 for high pressure supplies or BS EN 1287 for low pressure supplies. TMV2 valves are typically found on baths in houses and flats, including the baths in new homes that must be limited to 48°C under building regulations.

TMV3 is a higher-performance scheme intended for healthcare and similar settings. Its tests are based on the NHS D 08 specification, which asks more of the valve in terms of temperature stability, response to supply failure and suitability for particular outlets. TMV3 valves are what you would normally expect to find in hospitals, and they are commonly specified in care homes and other buildings used by people at higher risk of scalding.

Side by side

A quick comparison of the two schemes, read as rows of a table.

  • Intended use

    TMV2: domestic and domestic-type settings. TMV3: healthcare and similar settings with vulnerable users.

  • Test basis

    TMV2: BS EN 1111 (high pressure) or BS EN 1287 (low pressure). TMV3: the NHS D 08 performance specification.

  • Outlet designations

    TMV2: approval generally relates to the supply pressure. TMV3: approval is given for specific uses, such as washbasins, showers, bath fill or bidets, at high or low pressure.

  • Typical outlet settings

    TMV2: domestic baths are limited to 48°C in new homes. TMV3: D 08 recommends maximums of 38°C for bidets, 41°C for showers and washbasins, 44°C for baths, and up to 46°C for an assisted bath fill where a carer is present.

  • In-service testing

    TMV2: usually set by the manufacturer's instructions and the risk assessment. TMV3: D 08 sets out commissioning, in-service tests and intervals based on each valve's drift.

Which settings need which

  • Hospitals and clinics

    Healthcare guidance expects valves to meet the D 08 specification, so TMV3 is the norm.

  • Care and nursing homes

    Residents are often frail or have reduced sensation, and TMV3 valves are commonly specified. Many providers follow the D 08 testing routine too.

  • Schools, nurseries and supported housing

    The choice depends on the risk assessment. Where young children or vulnerable adults use outlets unsupervised, many duty holders choose TMV3.

  • Homes and general rented housing

    TMV2 valves are usually suitable for domestic baths, unless an occupant's needs point towards a higher specification.

  • Hotels, gyms and offices

    Either may be used. The risk assessment should consider who uses the outlets and how the supplies behave.

Dual-approved valves

Some valves hold both TMV2 and TMV3 approval. That gives flexibility: the same model can be used in a domestic bathroom or in a care setting. But dual approval does not mean a valve is automatically right for every outlet. Under TMV3, approval is linked to particular uses and pressures, so a valve approved for a washbasin at high pressure is not necessarily approved for bath fill at low pressure.

When a dual-approved valve is used in a healthcare-type setting, it should be set up, commissioned and tested to the D 08 approach, with the mixed temperature chosen for that outlet. Fitting a TMV3-capable valve and then treating it like a domestic valve misses most of the point.

Why supply pressure matters

Both schemes distinguish between low pressure and high pressure supplies. Low pressure usually means a gravity system fed from a cold water storage tank in the loft or roof space, with a vented hot water cylinder. High pressure usually means mains-fed cold, an unvented cylinder, a combination boiler or a pumped or boosted system.

A valve approved only for one pressure range may not hold its temperature, or may not shut off reliably on supply failure, if it is fitted on the other. Large differences between the hot and cold pressures can cause problems too, even within the right range. When a valve is being chosen or replaced, it helps to know how the hot and cold supplies are fed, and a survey can measure them if nobody is sure.

How to tell which valve you have

  • Look at the valve body

    Many valves carry markings on the body or cap showing the make, model and sometimes the scheme. A torch and a phone camera help when the valve is behind a panel.

  • Check the paperwork

    Installation records, commissioning sheets, previous service reports or an asset register may already list the model and its approval.

  • Use the model number

    Once you know the make and model, the manufacturer's literature normally states which scheme approvals apply and for which uses and pressures.

  • Ask for a survey

    On larger sites, a survey records every valve, its approval, its setting and its condition, which is often quicker than hunting through old files.

TMV2 and TMV3 questions

See all questions

Is TMV3 better than TMV2?

TMV3 is tested to a higher performance level, but the right valve is the one whose approval matches the setting and the supply pressures. A TMV3 valve fitted on the wrong pressure is not an improvement.

Can I replace a TMV3 valve with a TMV2 valve?

In a healthcare or care setting this would normally be a step down from what the guidance expects. Replacements should match or improve on the approval the risk assessment calls for.

Does a care home have to use TMV3?

No law names the scheme, but TMV3 is commonly specified for care settings because residents are at higher risk, and inspectors expect scald risk to be properly controlled.

Can one valve serve several outlets?

Some valves are approved to supply more than one outlet, but healthcare guidance generally prefers one valve per outlet, fitted close to it, to keep mixed-water runs short.

Do TMV2 valves need testing?

Yes. The manufacturer's instructions and the risk assessment set how often, and the same basic checks of temperature and fail-safe apply.

What if I cannot find any markings?

A partner engineer can usually identify the valve from its body and cartridge, or advise on replacement if it cannot be identified.